Nanovolume Spectrophotometer

Code

Nahita Nanovolume Spectrophotometers — Models Z-6500 and Z-6500C

€8,632.14 tax incl.
€7,134.00 Tax excl.
Spain 21% VAT; The final tax applicable may vary according to the country of destination.
Model
Available on Backorder

Nahita Nanovolume Spectrophotometers

Nahita nanovolume spectrophotometers are designed for the rapid and accurate quantification of nucleic acids, proteins and colourimetric assays in extremely small sample volumes. With advanced optical technology and an integrated digital system, they deliver precise results in just a few seconds, optimising performance in molecular biology, biotechnology and clinical analysis laboratories.

The system incorporates a long-life xenon light source that requires no warm-up time, together with a 3864-element silicon CCD detector offering high sensitivity and speed. The UV-Vis wavelength range from 200–900 nm enables versatile biomolecular analysis, while its ≤ 2 nm spectral resolution and ± 1 nm wavelength accuracy ensure reproducible measurements even at very low concentrations.

Compact and user-friendly, these devices feature a 7-inch high-definition touch screen with an integrated computer and pre-installed software requiring no additional setup. They include ≥ 32 GB of internal storage and allow result export in spreadsheet format via USB or local network. The stainless steel detection base with a quartz measurement point ensures long-term durability and precision.

Both models include two USB ports for external peripherals (mouse, keyboard, etc.) and use a split-beam optical system with adjustable path lengths of 1, 0.5 or 0.05 mm, offering maximum flexibility according to sample type. With a measurement cycle of ≤ 5 seconds and low power consumption (29 W), they are highly efficient for intensive laboratory use.

Model Comparison

Specifications Z-6500 Z-6500C
Detection mode Microscale Microscale / Cuvette
Sample volume (microscale) 0.3–2.5 μL 0.3–2.5 μL
Minimum cuvette volume — 50 μL
Minimum cuvette height — 5 mm
Cuvette chamber — Anechoic chamber for standard cuvettes
Wavelength range (UV-Vis) 200–900 nm
Protein / Nucleic acid range 220–360 nm
Microarray range 200–850 nm
Wavelength accuracy ± 1 nm
Spectral resolution ≤ 2 nm
Optical system Split beam
Optical path length 1 / 0.5 / 0.05 mm (adjustable)
Photometric range 0–300 A
Photometric accuracy 0.002 A
Light source Long-life xenon lamp
Detector 3864-element silicon linear CCD array
Nucleic acid range (dsDNA) 0.4–15,000 ng/μL
Protein range 0.1–400
Measurement cycle ≤ 5 s
Display / control 7" HD touchscreen with built-in PC and pre-installed software
Internal storage ≥ 32 GB
Data export USB or local network

Data sheet

Product Type
Spectrophotometer